FISHER 912N Series direct-operated

FISHER 912N Series direct-operated

912N Series direct-operated, spring-loaded regulators are used in service and industrial applications. These regulators have limited-capacity internal relief across the diaphragm to help minimize overpressure. Any outlet pressure above the start-to-discharge point of the non-adjustable relief valve spring moves the diaphragm off the relief valve seat, allowing excess pressure to bleed vent. 912N Series regulators are built to provide accurate, sensitive control.

Specifications

Body Size and End Connection Styles

Inlet: 1/4 NPT
Outlet: 1/4 or 3/8 NPT

Maximum Inlet Pressure

250 psig / 17,2 bar

Maximum Allowable Outlet Pressure

Emergency Outlet Pressure: 20 psig / 1,4 bar
Recommended Outlet Pressure to Avoid Internal Parts Damage: 3 psi / 0,21 bar differential above outlet pressure setting

Pressure Registration

Internal

Temperature Capabilities

-20 to 160°F / -29 to 71

Features

Accurate, Sensitive Control

Versatility

Weather and Insect Protection

Easy Maintenance